JMS-Q1600GC UltraQuad™ 2.0
แก๊สโครมาโตกราฟีสี่ขั้ว
แมสสเปกโตรมิเตอร์
The Next Generation of GC-QMS. Enhancing Qualitative Analysis by AI.
The JMS-Q1600GC UltraQuad™ 2.0 is a versatile, high-performance GC-QMS system for a wide range of qualitative and quantitative applications, from materials and aroma analysis to environmental, water quality, and agrochemical analysis.
msFineAnalysis IQ with the AI Structure Analysis Program delivers powerful performance for the qualitative analysis of unknown compounds.
คุณสมบัติ
A Unique Ion Source Expanding Your Solutions:
Soft Ionization via EI, CI, and PI
Soft ionization technique can be utilized for qualitative and quantitative analysis
The EI method is a hard ionization method, and many ions are observed, but often a molecular ion is not observed.
The UltraQuad™ 2.0 can utilize PI, CI, and Low-Energy EI as soft ionization methods to observe a molecular ion or ion-adduct molecule
that provides molecular weight information.
The soft ionization method can be applied to the work of confi rming the results of qualitative analysis by library database search and
quantitative analysis by taking advantage of selectivity.
Electron Ionization (EI)/Chemical Ionization (CI) Combination Ion Source (option)
CI is an SI method that provides molecular weight information by reacting with reagent gases. The newly designed EI/CI chamber allows you to switch ionization methods while maintaining vacuum, and the choice of reagent gases provides fl exibility for a wide variety of compounds.
Schematic diagram of EI/CI combination ion source
EI/CI combination ion source chamber
Electron ionization (EI)/Photoionization (PI) combination Ion Source (option)
PI is an SI method using a deuterium lamp. This combination ion source can be used for EI and PI methods. By simply turning on the EI fi lament or PI lamp, the ionization method can be switched instantaneously while maintaining vacuum for effi cient measurement.
แหล่งกำเนิดไอออนรวม EI/PI
Schematic diagram of EI/PI combination ion source
Comparison of mass spectra using EI/CI
and EI/PI combination ion sources
Sample: Pyrolysis product of acrylic resin
Solution for Reliable Quantitative Analysis:
Integrated Analysis + AI Structure Analysis
msFineAnalysis IQ is an optional qualitative analysis software dedicated to the JMS-Q1600GC and JMS-TQ4000GC. "Integrated analysis" provides more accurate analysis results than qualitative analysis based on NIST database search. In addition, even if no promising candidate is found through NIST search, structure estimation can be performed by "AI Structure Analysis".
การวิเคราะห์แบบบูรณาการTo a higher level of qualitative analysis, not limited to NIST search
In addition to NIST search results, the combination of molecular ion information, retention index, and isotope patterns obtained from SI spectra realizes more reliable qualitative analysis.

AI structure AnalysisElucidating the structure of unknown compounds
A mass spectrum library of 200 million compounds generated by AI dramatically accelerates the analysis of unknown compounds. Combined with the molecular weight information obtained from SI, it leads to rapid analysis.

ความไวสูงและช่วงไดนามิกที่ยอดเยี่ยม
Instrument Detection Limit (IDL)
Sequential measurements of OFN 20 fg achieved the IDL 2.6 fg, which is a statistical indicator (guaranteed to be 5 fg or less at the time of delivery*).
*Only when confi gured with an autosampler
ช่วงไดนามิก
The wide dynamic range of 1.6 × 107 is useful for both quantitative and qualitative analysis of samples with concentration differences.
Calibration curve of OFN (SIM)
Concentration range: 0.005 to 1,000 pg
High-Precision Analysis Not Limited to Helium
Delivers Reliable Results with Nitrogen Gas
To address rising helium prices and increasing supply uncertainty, helium consumption can be significantly reduced by the carrier gas saver and gas switching function. In addition, GC-MS measurement with an alternative carrier gas can be performed simply by changing the setting conditions, and JEOL has a proven track record of measuring with highly safe nitrogen gas, making it suitable for a variety of applications.
Note: There are alternative carrier gases that are not recommended for all preprocessing equipment.
การวิเคราะห์เชิงปริมาณ
Analysis of VOCs in water by trap HS-GC-MS using nitrogen carrier gas (MSTips No.416)
Measurements were performed from 1 µg/L for 1,4-dioxane and 0.1 µg/L for other VOCs, and high-sensitivity analysis which suffi ciently met regulatory requirements was achieved even for the nitrogen carrier gas.
SIM Chromatogram of
1 µg/L 1,4-Dioxane
SIM Chromatogram of
0.1 µg/L Carbon tetrachloride
Reproducibility and correlation coeffi cient at lowest concentration
(1,4-Dioxane: 1 µg/L, Other VOC: 0.1 µg/L)
การวิเคราะห์เชิงคุณภาพ
Aroma oil analysis using diff erent carrier gases (MSTips No.444)
The elution positions and EI spectra of all peaks were consistent for both helium and nitrogen, resulting in identical candidate compounds in the database search and the same candidate compounds were obtained. On the other hand, the peak positions and candidate compounds for hydrogen were diff erent, and the EI spectrum was also changed. Because the same molecular ion was detected in the PI spectrum, it is possible that the structural change occurred in the GC inlet and ion source due to the infl uence of the hydrogen carrier gas.

ดาวน์โหลดแคตตาล็อก
สินค้าที่เกี่ยวข้อง
msFineAnalysis IQ integrated qualitative analysis software
msFineAnalysis IQ is next‑generation GC‑QMS qualitative analysis software developed exclusively for the JMS‑Q1600GC and JMS‑TQ4000GC. It enables ‘AI structural anakysis,’ which integrates EI data with soft‑ionization data, together with advanced AI‑driven ‘AI Structure Analysis.’ By significantly enhancing conventional library‑search capabilities and enabling structural estimation of unknown compounds not contained in the NIST database, it greatly expands the analytical potential of GC‑QMS qualitative workflows.
เครื่องแก๊สโครมาโทกราฟ JMS-T2000GC AccuTOF™ GC-Alpha 2.0 - เครื่องวัดมวลสารแบบ Time-of-Flight
ระบบ GC-MS ขั้นสุดยอดที่มุ่งมั่นสู่ประสิทธิภาพและฟังก์ชันการทำงานขั้นสูงสุด JMS-T2000GC AccuTOF™ GC-Alpha ได้พัฒนาเป็นเวอร์ชัน “2.0” ด้วยการผสานรวมระบบป้อนตัวอย่างมาตรฐานแบบอัตโนมัติเต็มรูปแบบและปัญญาประดิษฐ์ msFineAnalysis AI เราช่วยให้สามารถวิเคราะห์โครงสร้างของสารที่ไม่ทราบชนิดได้โดยอัตโนมัติโดยใช้เทคโนโลยีหลักสามประการ ได้แก่ TOFMS ประสิทธิภาพสูง การแตกตัวเป็นไอออนแบบอ่อนที่สร้างไอออนโมเลกุลสำหรับสารวิเคราะห์ส่วนใหญ่ และการวิเคราะห์โครงสร้างด้วย AI
คลิกปุ่ม "เล่นซ้ำ" ในช่องด้านบน แล้วภาพยนตร์จะเริ่ม (เป็นเวลา 4 นาที)
เครื่องวิเคราะห์มวลสารแบบควอดรูโพลสามตัว JMS-TQ4000GC
ด้วยเซลล์การชนแบบสั้นและความสามารถ SRM ความเร็วสูง (สูงสุด 1,000 ช่อง/วินาที) เครื่อง JMS-TQ4000GC จึงให้ความไวและความสามารถในการประมวลผลที่ยอดเยี่ยมสำหรับการวิเคราะห์เชิงปริมาณหลายองค์ประกอบในงานด้านสิ่งแวดล้อม อาหาร และเคมี
ข้อมูลเพิ่มเติม